SGP-MC Series Circuit Breakers with Thermal-Magnetic Trip Units
Get consultation
Description
SGP-MC circuit breakers with thermal-magnetic trip units are available in 3-pole and 4-pole configurations and are designed to protect electrical circuits against overloads and short circuits with fixed settings
Auto switch Selectric SGP-MC Electromagnetic, standard size 63/25A, 50kA, 3P, Motor protection, undervoltage release and alarm contact, Fixed, Front connection, AC 230V
Code
SGP-MC-63S32382-25A-AC230V
Frame size, A
63
Rated current, A
25
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Electromagnetic
Built-in accessories
undervoltage release, alarm contact
Control circuits
AC 230V
Degree of protection
IP20
Price:
16 106 ₽
Auto switch Selectric SGP-MC Electromagnetic, standard size 63/25A, 50kA, 3P, Motor protection, undervoltage release , Fixed, Front connection, AC 230V
Code
SGP-MC-63S32302-25A-AC230V
Frame size, A
63
Rated current, A
25
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Electromagnetic
Built-in accessories
undervoltage release
Control circuits
AC 230V
Degree of protection
IP20
Price:
14 676 ₽
Auto switch Selectric SGP-MC Electromagnetic, standard size 63/25A, 50kA, 3P, Motor protection, shunt release and alarm contact, Fixed, Front connection, AC 230V
Code
SGP-MC-63S32182-25A-AC230V
Frame size, A
63
Rated current, A
25
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Electromagnetic
Built-in accessories
shunt release, alarm contact
Control circuits
AC 230V
Degree of protection
IP20
Price:
14 795 ₽
Auto switch Selectric SGP-MC Electromagnetic, standard size 63/25A, 50kA, 3P, Motor protection, shunt release, Fixed, Front connection, AC 230V
Code
SGP-MC-63S32102-25A-AC230V
Frame size, A
63
Rated current, A
25
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Electromagnetic
Built-in accessories
shunt release
Control circuits
AC 230V
Degree of protection
IP20
Price:
13 366 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and aux contact 1NO+1NC and alarm contact, Fixed, Front connection, DC 24V
Code
SGP-MC-63S3348-20A-DC24V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, aux contact (1 NO + 1 NC), alarm contact
Control circuits
DC 24V
Degree of protection
IP20
Price:
16 344 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and aux contact 1NO+1NO, Fixed, Front connection, DC 24V
Code
SGP-MC-63S3340-20A-DC24V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, aux contact (1NO+1NC)
Control circuits
DC 24V
Degree of protection
IP20
Price:
14 914 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and alarm contact, Fixed, Front connection, DC 24V
Code
SGP-MC-63S3318-20A-DC24V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, alarm contact
Control circuits
DC 24V
Degree of protection
IP20
Price:
14 795 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release, Fixed, Front connection, DC 24V
Code
SGP-MC-63S3310-20A-DC24V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release
Control circuits
DC 24V
Degree of protection
IP20
Price:
13 366 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and aux contact 1NO+1NC and alarm contact, Fixed, Front connection, DC 110V
Code
SGP-MC-63S3348-20A-DC110V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, aux contact (1 NO + 1 NC), alarm contact
Control circuits
DC 110V
Degree of protection
IP20
Price:
16 344 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and aux contact 1NO+1NO, Fixed, Front connection, DC 110V
Code
SGP-MC-63S3340-20A-DC110V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, aux contact (1NO+1NC)
Control circuits
DC 110V
Degree of protection
IP20
Price:
14 914 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and alarm contact, Fixed, Front connection, DC 110V
Code
SGP-MC-63S3318-20A-DC110V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, alarm contact
Control circuits
DC 110V
Degree of protection
IP20
Price:
14 795 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release, Fixed, Front connection, DC 110V
Code
SGP-MC-63S3310-20A-DC110V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release
Control circuits
DC 110V
Degree of protection
IP20
Price:
13 366 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and aux contact 1NO+1NC and alarm contact, Fixed, Front connection, DC 230V
Code
SGP-MC-63S3348-20A-DC230V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, aux contact (1 NO + 1 NC), alarm contact
Control circuits
DC 230V
Degree of protection
IP20
Price:
16 344 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and aux contact 1NO+1NO, Fixed, Front connection, DC 230V
Code
SGP-MC-63S3340-20A-DC230V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, aux contact (1NO+1NC)
Control circuits
DC 230V
Degree of protection
IP20
Price:
14 914 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and alarm contact, Fixed, Front connection, DC 230V
Code
SGP-MC-63S3318-20A-DC230V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, alarm contact
Control circuits
DC 230V
Degree of protection
IP20
Price:
14 795 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release, Fixed, Front connection, DC 230V
Code
SGP-MC-63S3310-20A-DC230V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release
Control circuits
DC 230V
Degree of protection
IP20
Price:
13 366 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, undervoltage release and aux contact 1NO+1NC and alarm contact, Fixed, Front connection, AC 400V
Code
SGP-MC-63S3378-20A-AC400V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
undervoltage release, aux contact (1 NO + 1 NC), alarm contact
Control circuits
AC 400V
Degree of protection
IP20
Price:
17 654 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, undervoltage release and aux contact 1NO+1NC, Fixed, Front connection, AC 400V
Code
SGP-MC-63S3370-20A-AC400V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
undervoltage release, aux contact (1NO+1NC)
Control circuits
AC 400V
Degree of protection
IP20
Price:
16 225 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and aux contact 1NO+1NC and alarm contact, Fixed, Front connection, AC 400V
Code
SGP-MC-63S3348-20A-AC400V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, aux contact (1 NO + 1 NC), alarm contact
Control circuits
AC 400V
Degree of protection
IP20
Price:
16 344 ₽
Auto switch Selectric SGP-MC Thermomagnetic, standard size 63/20A, 50kA, 3P, Power distribution protection, shunt release and aux contact 1NO+1NO, Fixed, Front connection, AC 400V
Code
SGP-MC-63S3340-20A-AC400V
Frame size, A
63
Rated current, A
20
Rated AC operating voltage: Ue, V; 50/60 Hz
400В
Breaking capacity level Icu
S
Breaking capacity level Icu , at AC 400V, kA
50
Trip unit type
Thermomagnetic
Built-in accessories
shunt release, aux contact (1NO+1NC)
Control circuits
AC 400V
Degree of protection
IP20
Price:
14 914 ₽